Preview

Innovative Medicine of Kuban

Advanced search

Factors influencing the pedicle screw fixation stability in patients with unstable lumbar and thoracolumbar spine injuries

https://doi.org/10.35401/2500-0268-2020-19-3-12-19

Abstract

Background. One of the reasons for the lack of standardized approaches to treating lumbar and thoracolumbar spine traumatic injuries is inconclusive information on relative contribution of various factors to pedicle screw fixation stability.

Objective. To determine risk factors that influence pedicle screw fixation stability in patients with unstable traumatic injuries of a lumbar spine and thoracolumbar junction.

Material and Methods. This was a retrospective evaluation of 192 spinal instrumentations. Patients with type А3, A4, B1, B2 and C injuries of lumbar and thoracolumbar spine were enrolled. Pedicle screw fixation was used either as a stand-alone technique or in combination with anterior column reconstruction. If required, decompression of nerve roots and spinal cord was performed. Cases with pedicle screw fixation failure were registered. Logistic regression analysis was used to assess predictive significance of potential risk factors.

Results. Complication rate growth was associated with a decrease in bone radiodensity, posterior decompression extensiveness, lumbosacral fixation and residual kyphotic deformity. Anterior column reconstruction and additional pedicle screw installation led to a decline in complication rate while anterior decompression and fixation length did not influence fixation stability.

Conclusion. In most cases, pedicle screw fixation system failure is associated with altered bone quality; however, surgical approach may also impact complication rate and should be taken into account when planning surgical intervention. Anterior column reconstruction and additional pedicle screw installation are associated with the decline in complication rate; the influence of those options is comparable. Anterior decompression does not influence pedicle screw fixation stability; consequently, it is preferable in cases with considerable risk of pedicle screw fixation failure.

About the Authors

A. E. Bokov
Privolzhsky Research Medical University
Russian Federation

Andrey E. Bokov, Cand. of Sci. (Med.), Head of the Oncology and Neurosurgery Department, Institute of Traumatology and Orthopedics

ploshchad Minina i Pozharskogo, 10/1, Nizhny Novgorod, 603005



S. G. Mlyavykh
Privolzhsky Research Medical University
Russian Federation

Sergey G. Mlyavykh, Cand. of Sci. (Med.), Chief of the Institute of Traumatology and Orthopedics

Nizhny Novgorod



I. S. Brattsev
Privolzhsky Research Medical University
Russian Federation

Ivan S. Brattsev, Neurosurgeon, Oncology and Neurosurgery Department, Institute of Traumatology and Orthopedics

Nizhny Novgorod



A. V. Dydykin
Privolzhsky Research Medical University
Russian Federation

Andrey V. Dydykin, Cand. of Sci. (Med.), Neurosurgeon, Oncology and Neurosurgery Department, Institute of Traumatology and Orthopedics

Nizhny Novgorod



References

1. Melton LJ, Kallmes DF. Epidemiology of vertebral fractures: implications for vertebral augmentation. Acad Radiol. 2006;13:538–45. PMID: 16627192. doi:10.1016/j.acra.2006.01.005

2. Sebaaly A, Rizkallah M, Riouallon G, et al. Percutaneous fixation of thoracolumbar vertebral fractures. EFORT Open Rev. 2018;3:604–13. PMID: 30595846. PMCID: PMC6275852. doi:10.1302/2058-5241.3.170026

3. Ye C, Luo Zh, Yu X, Liu H, Zhang B, Dai M. Comparing the efficacy of short-segment pedicle screw instrumentation with and without intermediate screws for treating unstable thoracolumbar fractures. Medicine (Baltimore). 2017;96:e7893. PMID: 28834906. PMCID: PMC5572028. doi:10.1097/MD.0000000000007893

4. Mohi Eldin MM, Ali AM. Lumbar transpedicular implant failure: a clinical and surgical challenge and its radiological assessment. Asian Spine J. 2014;8:281–97. PMID: 24967042. PMCID: PMC4068848. doi:10.4184/asj.2014.8.3.281

5. Galbusera F, Volkheimer D, Reitmaier S, Berger-Roscher N, Kienle A, Wilke H-J. Pedicle screw loosening: a clinically relevant complication? Eur Spine J. 2015;24:1005–16. PMID: 25616349. doi:10.1007/s00586-015-3768-6

6. Sodhi HBS, Savardekar AR, Chauhan RB, Patra DP, Singla N, Salunke P. Factors predicting long-term outcome after short-segment posterior fixation for traumatic thoracolumbar fractures. Surg Neurol Int. 2017;8:233. PMID: 29026669. PMCID: PMC5629846. doi:10.4103/sni.sni_244_17

7. Gumussuyu G, Islam NC, Kose O, Gungor M, Ozcan H. Comparison of two segment combined instrumentation and fusion versus three segment posterior instrumentation in thoracolumbar burst fractures: a randomized clinical trial with 10 years of follow up. Turk Neurosurg. 2019;29:555–63. PMID: 30900733. doi:10.5137/1019-5149.JTN.25025-18.3

8. Wang J, Liu P. Analysis of surgical approaches for unstable thoracolumbar burst fracture: minimum of five year follow-up. J Pak Med Assoc. 2015;65:201–5. PMID: 25842559.

9. Joaquim AF, Maslak JP, Patel AA. Spinal reconstruction techniques for traumatic spinal injuries: a systematic review of biomechanical studies. Global Spine J. 2019;9:338–47. PMID: 31192103. PMCID: PMC6542174. doi:10.1177/2192568218767117

10. Schnake KJ, Stavridis SI, Kandziora F. Five-year clinical and radiological results of combined anteroposterior stabilization of thoracolumbar fractures. J Neurosurg Spine. 2014;20:497–504. PMID: 24606000. doi:10.3171/2014.1.SPINE13246

11. Norton RP, Milne EL, Kaimrajh DN, Eismont FJ, Latta LL, Williams SK. Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures. Spine J. 2014;14:1734–9. PMID: 24462814. doi:10.1016/j.spinee.2014.01.035

12. Bisschop A, van Engelen SJ, Kingma I, et al. Single level lumbar laminectomy alters segmental biomechanical behavior without affecting adjacent segments. Clin Biomech (Bristol, Avon). 2014;29:912–7. PMID: 25028214. doi:10.1016/j.clinbiomech.2014.06.016

13. Lee MJ, Bransford RJ, Bellabarba C, et al. The effect of bilateral laminotomy versus laminectomy on the motion and stiffness of the human lumbar spine: a biomechanical comparison. Spine (Phila Pa 1976). 2010;35:1789–93. PMID: 20562732. doi:10.1097/BRS.0b013e3181c9b8d6

14. Weiser L, Huber G, Sellenschloh K, et al. Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength. Eur Spine J. 2017;26:2891–7. PMID: 28391382. doi:10.1007/s00586-017-5091-x

15. Zaidi Q, Danisa OA, Cheng W. Measurement techniques and utility of hounsfield unit values for assessment of bone quality prior to spinal instrumentation: a review of current literature. Spine (Phila Pa 1976). 2019;44:E239–E244. PMID: 30063528. doi:10.1097/BRS.0000000000002813

16. Bredow J, Boese CK, Werner CM, et al. Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery. Arch Orthop Trauma Surg. 2016;136:1063–7. PMID: 27312862. doi:10.1007/s00402-016-2487-8

17. Afaunov AA, Basankin IV, Mishagin AV, Kuzmenko AV, Takhmazyan KK. Revision procedures in the surgical treatment of thoracic and lumbar spine injuries. Journal of Spine Surgery. 2015;12(4):8–16. (In Russ.). doi:10.14531/ss2015.4.8-16

18. Yu BS, Zhuang XM, Zheng ZM, Zhang JF, Li ZM, Lu WW. Biomechanical comparison of 4 fixation techniques of sacral pedicle screw in osteoporotic condition. J Spinal Disord Tech. 2010;23:404–9. PMID: 20087222. doi:10.1097/BSD.0b013e3181b63f4d

19. Reinhold M, Knop C, Beisse R, et al. Operative treatment of 733 patients with acute thoracolumbar spinal injuries: comprehensive results from the second, prospective, internet-based multicenter study of the Spine Study Group of the German Association of Trauma Surgery. Eur Spine J. 2010;19:1657–76. PMID: 20499114. PMCID: PMC2989217. doi:10.1007/s00586-010-1451-5

20. Sait A, Prabhav NR, Sekharappa V, Rajan R, Raj NA, David KS. Biomechanical comparison of short-segment posterior fixation including the fractured level and circumferential fixation for unstable burst fractures of the lumbar spine in a calf spine model. J Neurosurg Spine. 2016;25:602–9. PMID: 27285665. doi:10.3171/2016.4.SPINE1671

21. Altay M, Ozkurt B, Aktekin CN, Ozturk AM, Dogan O, Tabak AYa. Treatment of unstable thoracolumbar junction burst fractures with short- or long-segment posterior fixation in magerl type a fractures. Eur Spine J. 2007;16:1145–55. PMID: 17252216. PMCID: PMC2200786. doi:10.1007/s00586-007-0310-5

22. McDonnell M, Shah KN, Paller DJ, et al. Biomechanical analysis of pedicle screw fixation for thoracolumbar burst fractures. Orthopedics. 2016;39:e514–18. PMID: 27135451. doi:10.3928/01477447-20160427-09

23. Bolesta MJ, Caron T, Chinthakunta SR, Vazifeh PN, Khalil S. Pedicle screw instrumentation of thoracolumbar burst fractures: biomechanical evaluation of screw configuration with pedicle screws at the level of the fracture. Int J Spine Surg. 2012;6:200–5. PMID: 25694892. PMCID: PMC4300899. doi:10.1016/j.ijsp.2012.09.002

24. Seo DK, Kim ChH, Jung SK, Kim MK, Choi SJ, Park JH. Analysis of the risk factors for unfavorable radiologic outcomes after fusion surgery in thoracolumbar burst fracture: what amount of postoperative thoracolumbar kyphosis correction is reasonable? J Korean Neurosurg Soc. 2019;62:96–105. PMID: 29940722. PMCID: PMC6328790. doi:10.3340/jkns.2017.0214

25. Mizuno T, Kasai Yг, Sakakibara T, Yoshikawa T, Inaba T. Biomechanical study of rotational micromovement of the pedicle screw. Springerplus. 2016;5:1016. PMID: 27441135. PMCID: PMC4938808. doi:10.1186/s40064-016-2694-3

26. Mehmanparast H, Petit Y, Mac-Thiong JM. Comparison of pedicle screw loosening mechanisms and the effect on fixation strength. J Biomech Eng. 2015;137:121003. PMID: 26502116. doi:10.1115/1.4031821

27. Schreiber JJ, Hughes AP, Taher F, Girardi FP. An association can be found between hounsfield units and success of lumbar spine fusion. HSS J. 2014;10:25–9. PMID: 24482618. PMCID: PMC3903949. doi:10.1007/s11420-013-9367-3

28. Bulkin AA, Bokov AE, Mlyavykh SG. Factors affecting bone formation in patients with degenerative lumbar spine pathology. Russian Neurosurgical Journal Named after Professor Polenov. 2019;11(2):12–16 (In Russ.).


Review

For citations:


Bokov A.E., Mlyavykh S.G., Brattsev I.S., Dydykin A.V. Factors influencing the pedicle screw fixation stability in patients with unstable lumbar and thoracolumbar spine injuries. Innovative Medicine of Kuban. 2020;(3):12-19. (In Russ.) https://doi.org/10.35401/2500-0268-2020-19-3-12-19

Views: 859


ISSN 2541-9897 (Online)